Key takeaways
- 25 g of serum in a 30 ml cavity leaves about 5 ml of air, a workable single-mask ratio.
- Some headspace is functional: it keeps serum off the seal during the fill stroke.
- Excess air lets serum migrate to the headspace and dries the mask at the fold first.
- A 6-8 mm seal with contaminated band passes visual check and fails under a pallet.
- Change the cavity only when mask size or serum load moves by more than about 20 percent.
A face mask sachet is usually quoted by cavity volume and serum weight, and the difference between the two is headspace. Too little and the seal is contaminated during filling; too much and the mask sits above the serum, dry at the fold when the customer opens it.
1. Cavity volume and fill weight
A 25 g serum load in a 30 ml cavity leaves roughly 5 ml of air. That ratio is a common starting point for a single sheet mask. It is not a standard: cavity volume depends on mask dimensions folded to fit, and a larger mask in the same cavity reduces headspace without changing the serum load.
2. Why some air is necessary
The sachet has to be formed, filled and sealed at speed. Air gives the film something to push against and keeps serum away from the seal zone during the fill stroke. A sachet filled to the brim splashes, and a splash across the seal area is the most common cause of a leaker in a good batch.
3. Too much air and the mask dries
Air is a reservoir for water vapour. Over months, serum migrates into the headspace and the top fold of the mask loses moisture first. The customer sees a patchy, semi-dry sheet at the fold and reads it as a quality fault, which it is, even though the total serum weight is on specification. The effect runs faster in a clear film than in a laminate, so one headspace can be acceptable in one pack and a complaint in the other.
4. Seal width and contamination
A 6-8 mm seal is typical. Serum trapped in that band during sealing produces a weak weld that passes a visual check and fails in a pallet. Keeping the fill nozzle below the seal line and leaving headspace to absorb the surge is cheaper than adding an inspection step.
5. Film stiffness sets the limit
A stiff laminate holds a cavity shape and tolerates more headspace without the mask sliding. A softer clear film collapses and presses the mask against the seal. The same fill weight therefore behaves differently in two films, which is why a film change is a fill trial and not a purchasing decision.
6. Folding pattern matters
A mask folded in three sits lower in the cavity than one folded in four. The fold also decides where the dry edge appears. Agreeing the fold with the die line, before the cavity is ordered, avoids a situation where the sachet is correct and the mask presentation is wrong.
7. Testing headspace without a lab
Weigh ten sachets, store them on edge for two weeks at elevated temperature, then open and weigh the mask separately from the drained serum. Keep the sachets flat rather than stacked, because pressure on a soft film pushes serum toward the seal and confounds the result. A mask that has lost more than a few percent of its serum share indicates too much headspace or a film that transmits too much vapour.
8. When to change the cavity
Only when the mask dimensions change or the serum load moves by more than about 20 percent. Below that, adjusting the fill weight or the fold is cheaper and does not require new forming tooling. A cavity change also resets the carton and the pallet pattern.
9. Specification to hand a supplier
Give mask dimensions, fold pattern, serum weight, cavity volume, film structure and seal width. Those six values define the pack completely. A brief that gives only the serum weight leaves the supplier to choose the other five, and the choice will be the one that runs fastest.
10. Where it fits
Sheet mask and patch sachets with stated fill weights are listed in sheet mask formats, eye patch sachets and the encyclopedia.
Reference: Formats and filling notes, 2025