A formula that passes the challenge test in glass can fail in a plastic bottle. Preservative can migrate into the pack, and the loss is invisible until a microbiological result arrives.

Packaging 4 min read 18 Nov 2026

Key takeaways

  • Preservatives can absorb into polyolefins, elastomers and cap liners over weeks.
  • Testing in glass and packing in plastic is the most common source of the gap.
  • Contact tests at elevated temperature show loss before a challenge test does.
  • Headspace partitioning removes volatile preservatives from the water phase.
  • Choosing the liner and the resin is often cheaper than raising the dose.

1. Where the preservative goes

A preservative has to sit in the water phase to work. In a plastic pack it can leave that phase in three ways: absorption into the polymer, absorption into an elastomer such as a pump gasket or dropper bulb, and partitioning into the headspace. Each removes active from where it is needed without changing the label, the appearance or the smell of the product.

2. Sorption into polyolefins

Polyethylene and polypropylene absorb lipophilic preservatives such as parabens, phenoxyethanol and some isothiazolinones. The amount depends on the preservative’s polarity, the polymer’s crystallinity and the contact area. Thin-walled bottles with a large surface-to-volume ratio lose proportionally more. A 200 ml HDPE bottle can take up a measurable share of the preservative within four weeks at 40 degrees.

3. Elastomers and the pump

Nitrile and silicone components in pumps, droppers and sprayers absorb more aggressively than the bottle body because they are softer and often have high surface area in fine geometries. A pump that is perfectly compatible with the formula chemically can still be the reason a preservative level falls. This is why a pack compatibility test that only fills the bottle misses the problem.

4. Headspace partitioning

Volatile preservatives, notably phenoxyethanol and some fragrance-bearing actives, distribute between the liquid and the air above it. A pack with a large headspace, such as a wide jar filled to 80 percent, holds more in the air and less in the product. The equilibrium shifts as the pack is opened and closed by the consumer, which is one reason in-use testing matters.

5. Formula side factors

Surfactants above their critical micelle concentration solubilise preservatives into micelles, reducing the free concentration available to act on microorganisms even though the assay shows the full amount present. pH matters as well: organic acid preservatives are only effective in the undissociated form, so a formula drifting toward neutral loses efficacy without losing assay.

6. How to measure the loss

Fill the commercial pack and a glass control with the same bulk, store both at 40 degrees for four and eight weeks, and assay the preservative in both. The difference is the loss attributable to the pack. Run the test on the finished pack including the closure, since the closure is often where the largest single loss occurs. Do this before the challenge test, not after.

7. Overage and its limits

Raising the dose to cover predicted loss works, but it has a ceiling: regulatory limits per preservative, irritation risk and cost. Overage also hides the problem rather than solving it, so the next pack change reopens it. Use overage only where the loss is small and well characterised, and document the assumption so a later reviewer understands why the formula sits above the minimum effective level.

8. Choosing the liner and resin

Where loss is significant, change the contact material before changing the formula. A different liner, a coated closure, a fluorinated or barrier-treated surface, or a move from LDPE to a more crystalline resin can cut absorption substantially. Ask suppliers for sorption data rather than compatibility statements, since “compatible” usually means no visible attack, not no absorption.

9. What the challenge test misses

A challenge test run in a glass jar at laboratory scale validates the formula, not the packed product. A product can pass with a comfortable margin in glass and fail at the two-month mark in a pump bottle, at which point a recall is the only option. Pairing the challenge test with a pack contact study closes the gap, and both belong in the stability programme.

10. Where it fits

Preservative behaviour decides pack choice for body lotion and body scrub formats especially. Related pack notes are in encyclopedia, and format options are under products.

Reference: Pack compatibility study notes, 2025

Start a project

Ready to put your name on a formula?

Send a brief and our formulation team will come back with a costed proposal, sample plan and timeline — typically within two working days.

WhatsApp +86 13149918467
WeChat QR code Scan to add WeChat
Call +86 13149918467 [email protected]
Quote WhatsApp Call Products